 Dear CNCmakers,

  I try PLc Sep28Left004.LD2  output Analog Cn41 ,Cn42
 H1 = S1000 m3   Analog Output Cn41 Pin 1 -2  OK
         S1000m63  Analog Output Cn41 Pin 1-2 not Out Pin 4 - 5  it wrong
 
H2 = s1000 m3  Analog Output Cn42 Pin 1 - 2  Output OK    
        s1000 m63  Analog output Cn42 Pin 1-2  not Output 4-5  it Wrong
 Para 1970
    1-1 = -1
     2-1= -2
     1-2 = -3
      2-2= -4
 
and try PLC  STDPLC.LD2  problem Same Sep28Left004.LD2  Output Analog  Output 1 Chennel / CN41 and CN42
 
CNCmakes Support:

3700.1 need to be set as 1

-1 means pin 1 and pin 2 of cN41

-2 means pin 4 and pin 5 of cN41

-3 means pin 1 and pin 2 of cN42

-4 means pin 4 and pin 5 of cN42

Tested that 4 ways has analog output

If still not success, please send the parameters back, we will try again

In both channels, please execute both M3S1000 and M63S1000, and then check the 4 way analog output