1. First open the diagnostic screen:
1) Press the [SYSTEM] key
2) Press the soft key [Diagnosis] to enter the diagnosis screen
 
2. Then press the [PAGEDOWN↓] key several times to find the diagnosis as follows:
1) Check if the servo motor is overheated
 
 
2) Servo motor and encoder temperature
 
 
3) Spindle motor temperature
 
 
 
3 The display method of machine tool load is as follows:
 
 
In the vertical machining center, the Z axis load is relatively large, and some machine tools may be more than 50%, but the Z axis load exceeds 80% for a long time, the life of the Z axis motor will have a great impact, you can add a separate Z axis motor Cooling fan.
 
4 The FANUC fan is a consumable product. There are fans in the servo drive, CNC system and spindle motor. When idle maintenance, according to the situation of the electrical cabinet, replace it in time.
① System fan, +24V, three-wire. If there is an alarm 701, it can be shielded with the parameter 8109#1.
② Fans on power supply, servo and spindle drive.
 
 
 
 
 
The internal fan of the power drive, as shown below: