The latest FANUC system OIF adds an automatic data backup function, and it automatically backs up data when power is on, and backs up data from the battery-stored SRAM to ROM, so that even if the battery is dead, the machine data will not be lost.
The operation is as follows:
1 Modify the parameters as follows:
![]()
10340.0 (ABP)=1, the automatic data backup function is turned on when the power is turned on.
10340.2 (AAP)=1, the NC program and directory information backup of FROM is valid
10341 BACKUP INTERVAL=10 Back up data every 10 days
10342 BACKUP TIME =3 Number of backup data 3.
10340.1 (ABI)=1, it is forbidden to overwrite the backup data.
2 Power on and hold down the soft key, the two on the far right enter the BOOT screen.
![]()
BOOT screen
![]()
Select 7 items to enter the screen, as follows:
![]()
Option 3, AUTO BKUP RESTORE (automatically restore data from FROM to CNC RAM)
![]()
According to the time point of the backup, select the data you want to restore, and click to restore it directly.
|