GSK 218MC/GSK218MC-H/GSK218MC-V Alarm List

GSK 218MC/GSK218MC-H/GSK218MC-V Alarm List



Table4 The definition of the PLC extermal alarm
PMC
alarm No.
A add. Alarm Content
1200 A000.0 Air pressure detection abnormality
1201 A000.1 Lubrication detection abnormality
1202 A000.2 Lubricating motor detection abnormality
1203 A000.3 Cooling motor overload
1204 A000.4 Chip-removal motor detection abnormality
1205 A000.5 Pressure grease pump motor detection abnormality
1207 A000.7 Machine llumination lamp detection abnormality
1208 A0010 Machine controllable cabinet temperature detection abnormality
1209 A001.1 Machine body temperature detection abnormality
1210 A001,2 Machine vibration frequency detection abnormality
1211 A001.3 Pressure grease temperature detection abnomality
1212 A0014 Excessive low of the pressure grease
1213 A0015 Fail to ready the machine
1214 A0016 Fail to rotate the spindle because its shift is abnormal
1215 A001.7 Firstly perform the T code and then execute the M06 code
1216 A002.0 Fail to rotate the spindle in the tool releasing state
1217 A002.1 Spindle rotation tool can not be released
1218 A002.2 Tool magazine abnormal stop, confirm the tool number again
1219 A002.3 Fail to rotate the spindle because the manipulator is out of the origin
1220 A002.4 Spindle tool clamping detection abnormality
1221 A002.5 Spindle tool releasing detection abnormality
1222 A002.6 Spindle unit temperature detection abnormality
1223 A002.7 Spindle velocity detection abnormality
1224 A003.0 Spindle motor enabling detection abnormality
1225 A003.1 Spindle orientation in-position detection abnormality
1226 A003.2 Spindie shift abnormality
1227 A003.3 Failure to cycle start because the manipulator is out of the origin
position
1228 A003.4 Failure to cycle start because the tool case is in the vertical position.
1229 A003.5 Firstly perform the mechanical zero return when executing the M06
code
1230 A003.6 Fail to perfom the tol-change when the spindle tool is in the releasing
state
1231 A003.7 Fail to perfom the tool-change when the tool case is not in the
horizontal position
1232 A004.0 Tool magazine rotation in-position detection abnormality
1233 A004.1 Tool magazine rotation motor overload
PMC
A add. Alarm Content
alarm No.
1234 A004.2 Manipulator motor overload
1235 A004.3 Tool magazine motion in-position detection abnormality
1236 A004.4 Tool magazine zero turn detection abnormality
1237 A004.5 Tool magazine origin position lost, return to the zero again
1238 A004.6 Tool case horizontal/vertical detection abnormality
1239 A004.7 Fail to rotate the spindle because the tool case is out of the horizontal
position
1240 A005.0 Tool magazine abnormality, return to the zero again
1241 A005.1 Tool case vertical direction detection abnormality
1242 A005.2 Tool case horizontal direction detection abnormality
1243 A005.3 Tool magazine zero position setting enabled
1244 A005.4 Tool-change abnormal stop to sure the normal tool magazine
1245 A005.5 There is no code tool number in the table or code tool number is
repeated
1246 A005.6 Spindle releasing/clamping detection abnormality
1247 A005.7 Spindle orientation time-sequence detection abnormality
1248 A006.0 Adequate condition for T code tool number
1249 A006.1 Fail to infeed but the spindle is with tool
1250 A006.2 Fail to infeed because the current tool number is different between the
spindle and tool magazine
1251 A006.3 Turn off the power
1252 A006.4 Do not move the Z axis when tool clamping
1253 A006.5 Carefully operate the tool magazine debugging mode
1254 A006.6 Do not cycle start in the tool magazine debugging mode
1255 A006.7 Fail to return to the origin when tool clamping
1256 A007.0 Fail to the tool-change position when tool clamping
1257 A007.1 Fail to return to the tool-change position because the spindle under
positioning
1258 A007.2 Fail to return to the tool-change position because the tool abnormality
1260 A007.4 Do not cycle start in the manual tool-change position return
1261 A007.5 Fail to retract due to out of the origin
1262 A007.6 Exceed the safety position
1263 A007.7 Carefully operate the manipulator debugging mode
1264 A008.0 Spindle velocity position mode conversion abnormality
1265 A008.1 Spindle position velocity mode conversion abnormality
1267 A008.3 Fail to operated because the tool case does not vertical to the
manipulator
1268 A008.4 Fail to operate because the manipulator does not at the origin
1269 A008.5 Manipulator operation abnormality interruption
1270 A008.6 Manipulator tool inspection abnormality
1271 A008.7 Fail to operate the manipulator because the spindle does not orientate
1272 A009.0 Fail to operate the manipulator because the spindle tool does not

PMC
alarm No.
A add. Alarm Content
    release
1273 A009.1 Fail to operate the manipulator because the spindle tool does not
clamp
1274 A009.2 Do not perform the tool-pivoting because the manipulator does not at
the origin
1275 A009.3 Do not perform the tool-retraction because the manipulator does notat
the origin
1276 A009.4 Do not rotate the cutter-head because the manipulator does not at the
origin
1277 A009.5 Do not rotate the cutter-head because the tool case does not put on
the horizontal place
1278 A009.6 The manipulator can not be operated because the Z axis does not
return to the 2nd reference position.
1279 A009.7 Manipulator origin detection abnormality
1280 A010.0 Enforce to stop the rotation because the tool magazine rotation
abnormality
1288 A011.0 Index worktable releasing/clamping detection overtime
1289 A011.1 Index worktable clamping/releasing detection abnormality
1290 A011.2 Fail to use the index worktable clamping equipment
1291 A011.3 Fail to rotate because the index worktable does not release
1292 A011.4 Fail to move because the index worktable does not clamp
1293 A011.5 Do not cycle start because the safety door opens
1294 A011.6 Do not shift in the rigid tapping, it is necessary to cancel the rigid
tapping and then shift.
1 360 A020.0 Low lubrication pressure grease level










  

 
  
 