GSK 980TDi + GR2000 + A6 motor User:
The problem I have know is setting the gear ratio.
I have a lead screw of 5mm
Lead screw Gear teeth: 19
motor Gear teeth: 19
I don’t know witch encoder I Have, the motor is 80SJTA-M032E(A6)
The machine came default with parameters:
0015 x:5
0015 z:10
0016 x:3
0016 z:3
0008:00011111
With this data can you tell me what to set in order for the axis to move accordinlly with distance?
CNCmakers Support:
Please enter level 2 with password, then find attached page and enter the values of your machine.
The GSK 980TDi will calculate the gear ratio automatically.
|