Turning CNC Controller GSK980TB User: Could you tell us the lubrication time setting parameters of GSK980TB system?
CNCmakers Support: When the NO:13#2 JLB set as "0", the lubrication will be sustainable supply. When the NO:13#2 JLB set as "1", the lubrication will be intermittent supply, and the lubrication time will be determined by Parameter P107 (P101 for GSK98T system), stop time will be determined by parameter P108 (P102 for GSK98T system). |