Products Catalogue Home     |     About Us    |     Retrofit     |     Download     |     News     |     Tech Support     |     Contact Us     |     
ppr fittings-NF-4011-Newsun Industry Co., Ltd
Home > Tech Support >

Power turret alarm

Power turret alarms while change to the No.3 tool, no matter under Jog or MDI mode. And there is emergency alarm as well.

 

Normally this problem could be below reasons:

1-      The feedback cable of No.3 tool is shorted.

2-      The inductive sensor inside the power turret is shorted.

3-      The mechanical parts of the power turret stuck, causes switch trip off and then emergency alarms.

4-      Parameters of the CNC controller has mistakes.

 

Check step by step, we measured the resistance value of No.3 tool is different with other 3 tools, change the inductive sensor, the power turret resumed.


—[Close]— —[ Back]— —[ Print]—