Control GSK 983 Ma-H RV2.8.2.1 User: Dear Sirs of CNCMAKER: I have a control GSK 983 Ma-H RV2.8.2.1 VB and does not complete the initialization..Screens showing ; WAITING FOR TO READY READ CMOS MEMORY NOT READY. Permanently maintained in NOT READY I would need some suggestions and send me the following manuals: - Parameters Manual for GSK983Ma-H Version RV2.8.2.1 - Commissioning / Sevice Manuals for GSK983Ma-H Version RV2.8.2.1 - Procedure for uploading parameters and PLC files.
CNCmakers Support: The alarms means the CNC controller GSK983Ma has not received I/O signal. There are two sources of I/O signal, one from the I/O unit, another from the keyboard. So please check the wiring between GSK983Ma and I/O unit, controller to I/O unit. and check the keyboard connection too, upper panel to lower panel. |