|  Fanuc SYS_ALM501 SRAM DATA ERROR(BATTERY LOW DURING POWER OFF)
 The system alarm screen will be transferred when the system detects a condition that does not maintain normal system action.
 
 When entering the system alarm state, the system will:
 
 - Disconnect the excitation of servo and spindle amplifier
 
 - Disconnect I/O Link communication
 
 When a system alarm occurs, it switches to the screen shown below. This screen is called the system alarm screen.
 
 
  
 
 
 System alarms can be categorized into the following three types.
 
 - Alarms detected by software
 
 - Alarms detected by hardware
 
 - Other alarms
 
 
 
 1
 
 Alarms detected by software
 
 Software abnormalities are detected mainly by the CNC system software. Typical causes of abnormalities are:
 
 - Detection of processing/data conflicts based on internal status monitoring software
 
 - Access outside the data/command range
 
 - Divide by zero
 
 - Stack overflow
 
 - Stack overflow
 
 - DRAM sum check error
 
 2
 
 Alarms Detected by Hardware
 
 Hardware anomalies are detected primarily by the hardware. Typical causes of anomalies are:
 
 - Parity error (DRAM, SRAM, Hyper Cache)
 
 - Bus error
 
 - Power alarms
 
 - FSSB cable disconnection
 
 3
 
 Other Alarms
 
 Other causes are:
 
 - Alarms detected by peripheral software
 
 - Servo software (watchdog, etc.)
 
 - PMC software (I/O Link communication abnormality, etc.)
 |