As soon as you turn on the power of 983Ma, please keep press the SHIFT key until there is Administration Menu appears, you can enter the Password “983”to get to setting area, then you can set Z and A as 0 to disable them and remove the 436 alarm.
But the Z and A axies will be still displayed on the screen, just they are not in use any more.
|